Sign In | Join Free | My hardware-wholesale.com
China Shanghai Korain Biotech Co., Ltd logo
Shanghai Korain Biotech Co., Ltd
Shanghai Korain Biotech Co Ltd
Active Member

7 Years

Home > Human ELISA Kit >

Human AT3 Enzyme Linked Immunosorbent Assay High Specificity For Research

Shanghai Korain Biotech Co., Ltd
Contact Now

Human AT3 Enzyme Linked Immunosorbent Assay High Specificity For Research

Brand Name : BT Lab

Model Number : Cat.No E4267Hu

Certification : CE, ISO9001:2005, MSDS

Place of Origin : Shanghai, China

MOQ : Negotiation

Price : Negotiation

Supply Ability : Western Union, T/T

Delivery Time : 1-3 business days, bulk order within one week

Packaging Details : Wrapped with ice pack and styrofoam package

Delivery : Within 48 hours

Sample : Serum,plasma,urine,tissue,cell culture supernatant

OEM : Acceptable

Known as : AT3

Bulk Order : Yes

Target Protein : Antithrombin 3

Contact Now

High Specificity and Sensitivity Human AT3 Enzyme-linked Immunosorbent Assay Kit For Research

Cat.No E4267Hu

Reagent Preparation

All reagents should be brought to room temperature before use.

Standard Reconstitute the 120μl of the standard (1280ng/ml) with 120μl of standard diluent to generate a 640ng/ml standard stock solution. Allow the standard to sit for 15 mins with gentle agitation prior to making dilutions. Prepare duplicate standard points by serially diluting the standard stock solution (640ng/ml) 1:2 with standard diluent to produce 320ng/ml, 160ng/ml, 80ng/ml and 40ng/ml solutions. Standard diluent serves as the zero standard(0 ng/ml). Any remaining solution should be frozen at -20°C and used within one month. Dilution of standard solutions suggested are as follows:

640ng/ml Standard No.5 120μl Original Standard + 120μl Standard Diluent
320ng/ml Standard No.4 120μl Standard No.5 + 120μl Standard Diluent
160ng/ml Standard No.3 120μl Standard No.4 + 120μl Standard Diluent
80ng/ml Standard No.2 120μl Standard No.3 + 120μl Standard Diluent
40ng/ml Standard No.1 120μl Standard No.2 + 120μl Standard Diluent

Standard Concentration Standard No.5 Standard No.4 Standard No.3 Standard No.2 Standard No.1
1280ng/ml 640ng/ml 320ng/ml 160ng/ml 80ng/ml 40ng/ml

Wash Buffer Dilute 20ml of Wash Buffer Concentrate 25x into deionized or distilled water to yield 500 ml of 1x Wash Buffer. If crystals have formed in the concentrate, mix gently until the crystals have completely dissolved.

Standard Curve Range: 5ng/ml - 1000ng/ml

Sensitivity: 2.96ng/ml

Size: 96 wells

Storage: Store the reagents at 2-8°C. For over 6-month storage refer to the expiration date keep it at -20°C. Avoid repeated thaw cycles. If individual reagents are opened it is recommended that the kit be used within 1 month.

*This product is for research use only, not for use in diagnosis procedures. It’s highly recommend to read this instruction entirely before use.

Assay Principle

This elisa kit is an Enzyme-Linked Immunosorbent Assay (ELISA). The plate has been pre-coated with human AT3 antibody. AT3 present in the sample is added and binds to antibodies coated on the wells. And then biotinylated human AT3 Antibody is added and binds to AT3 in the sample. Then Streptavidin-HRP is added and binds to the Biotinylated AT3 antibody. After incubation unbound Streptavidin-HRP is washed away during a washing step. Substrate solution is then added and color develops in proportion to the amount of human AT3. The reaction is terminated by addition of acidic stop solution and absorbance is measured at 450 nm.

Reagent Provided

Components Quantity
Standard Solution (1280ng/ml) 0.5ml x1
Pre-coated ELISA Plate 12 * 8 well strips x1
Standard Diluent 3ml x1
Streptavidin-HRP 6ml x1
Stop Solution 6ml x1
Substrate Solution A 6ml x1
Substrate Solution B 6ml x1
Wash Buffer Concentrate (25x) 20ml x1
Biotinylated human AT3 Antibody 1ml x1
User Instruction 1
Plate Sealer 2 pics
Zipper bag 1 pic

Summary

1. Prepare all reagents, samples and standards.

2. Add sample and ELISA reagent into each well. Incubate for 1 hour at 37°C.

3. Wash the plate 5 times.

4. Add substrate solution A and B. Incubate for 10 minutes at 37°C.

5. Add stop solution and color develops.

6. Read the OD value within 10 minutes.

Calculation of Result

Construct a standard curve by plotting the average OD for each standard on the vertical (Y) axis against the concentration on the horizontal (X) axis and draw a best fit curve through the points on the graph. These calculations can be best performed with computer-based curve-fitting software and the best fit line can be determined by regression analysis.


Product Tags:

enzyme immunoassay kit

      

enzyme assay kits

      
China Human AT3 Enzyme Linked Immunosorbent Assay High Specificity For Research wholesale

Human AT3 Enzyme Linked Immunosorbent Assay High Specificity For Research Images

Inquiry Cart 0
Send your message to this supplier
 
*From:
*To: Shanghai Korain Biotech Co., Ltd
*Subject:
*Message:
Characters Remaining: (0/3000)